FISHER SCIENTIFIC, CHEMICAL DIV. -- FERRIC CHLORIDE,SOLID,ANHYDROUS -- 6810-00-270-3252
=====================  Product Identification  =====================

Product ID:FERRIC CHLORIDE,SOLID,ANHYDROUS
MSDS Date:12/02/1994
FSC:6810
NIIN:00-270-3252
=== Responsible Party ===
Company Name:FISHER SCIENTIFIC, CHEMICAL DIV.
Address:1 REAGENT LANE
City:FAIR LAWN
State:NJ
ZIP:07410
Country:US
Info Phone Num:201-796-7100 OR 201-796-7523
Emergency Phone Num:201-796-7100/800-424-9300(CHEMTREC)
CAGE:1B464
=== Contractor Identification ===
Company Name:CHEMICAL COMMODITIES AGENCY, INC.
Address:27447 PACIFIC STREET
Box:City:HIGHLAND
State:CA
ZIP:92346-2640
Country:US
Phone:909-864-2310
CAGE:60777
Company Name:FISHER SCIENTIFIC CO.  CHEMICAL MFG DIV
Address:1 REAGENT LANE
Box:City:FAIRLAWN
State:NJ
ZIP:07410-2802
Country:US
Phone:201-796-7100
CAGE:1B464

=============  Composition/Information on Ingredients  =============

Ingred Name:FERRIC CHLORIDE (CERCLA), SOLID, ANHYDROUS
CAS:7705-08-0
RTECS #:LJ9100000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1 MG (FE)/M3
ACGIH TLV:1 MG (FE)/M3; 9495
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

=====================  Fire Fighting Measures  =====================

Extinguishing Media:DRY CHEM,CO2,WATERSPRAY,REG FOAM.LG
    FIRES:WATERSPRAY,FOG,REG FOAM.
Fire Fighting Procedures:MOVE CNTNR FRM FIRE AREA W/O RISK.APPLY
    COOLING WATER TO CNTNR FLAME-EXPO SIDES TIL WELL AFT FIRE IS
    OUT.STAY AWAY FRM TKS ENDS.AVOID BREATH CORR VAP.KEEP UPWIN
Unusual Fire/Explosion Hazard:NELGIGIBLE FIRE HAZARD WHEN EXPOSED TO
    HEAT OR FLAME.

=============  Exposure Controls/Personal Protection  =============

Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

HCC:C1
Boiling Pt:B.P. Text:599F,315C
Melt/Freeze Pt:M.P/F.P Text:583F,306C
Spec Gravity:2.9
pH:SUPPLE
Solubility in Water:SOLUBLE.
Appearance and Odor:NO ODOR,GREEN OR BLACK-BROWN,VERY
    DELIQUESCENT,HEXAGONAL LEAFLETS/PLATES,BLK PW

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ALLYL CHLORIDE,AROMATIC NOMOMERS,EPICHLOROHYDRIN,EHTYLENE
    OXIDE,METALS,POTASSIUM,SODIUM.STRONG OXIDIZERS.
Stability Condition to Avoid:REACTS W/WATER TO RELEASE TOXIC FUMES OF
    HCL.MAY BURN BUT DOES NOT IGN READILUY.AVOID EXCESSIVE
    HEAT/SPARKS/OPEN FLAMES.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.