DU PONT E I DE NEMOURS & CO INC -- DU000025 FREON 22 -- 6830-00-290-4375
=====================  Product Identification  =====================

Product ID:DU000025 FREON 22
MSDS Date:06/03/1997
FSC:6830
NIIN:00-290-4375
=== Responsible Party ===
Company Name:DU PONT E I DE NEMOURS & CO INC
Address:1007 MARKET STREET
Box:1635
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Info Phone Num:800-441-9442
Emergency Phone Num:800-424-9300 CHEMTREC
Preparer's Name:ENGINEERING & SAFETY
CAGE:18873
=== Contractor Identification ===
Company Name:DU PONT E I  DE NEMOURS AND CO INC   PETROCHEMICALS DEPT
Address:1251 BRANDYWINE BLDG
Box:City:WILMINGTON
State:DE
ZIP:19898
Phone:302-773-5676
CAGE:73925
Company Name:E.I. DUPONT DE NEMOURS & CO
Address:1007 MARKET STREET
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515;800-441-9442
CAGE:18873

=============  Composition/Information on Ingredients  =============

Ingred Name:CHLORODIFLUOROMETHANE (SARA 313) (CERCLA)
CAS:75-45-6
RTECS #:PA6390000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM; 9596
Ozone Depleting Chemical:2

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:4-HOUR LC-50 (RAT): 220,000 PPM
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF HIGH CONCENTRATIONS OF
    VAPOR IS HARMFUL & MAY CAUSE HEART IRREGULARITIES, UNCONSCIOUSNESS
    OR DEATH. INTENTIONAL MISUSE OR DELIBERATE INHALATION MAY CAUSE
    DEATH WITHOUT WARNING. VAPOR RED UCES OXYGEN AVAILABLE FOR
    BREATHING & IS HEAVIER THAN AIR. LIQUID CONTACT CAN CAUSE
    FROSTBITE.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
    OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:SKIN-FROSTBITE, DEFATTING, DRYNESS.
    EYES-IRRITATION, DISCOMFORT, TEARING, BLURRING OF VISION.
    INHALED-DIZZINESS, HEADACHE, CONFUSION, INCOORDINATION, LOSS OF
    CONSCIOUSNESS, IRREGULAR HEART BEAT.
Medical Cond Aggravated by Exposure:PRE-EXISTING DISEASES OF THE
    CANTRAL NERVOUS OR CARDIOVASCULAR SYSTEMS MAY HAVE INCREASED
    SUSCEPTIBILITY TO THE TOXICITY OF EXCESSIVE OVEREXPOSURES.

=======================  First Aid Measures  =======================

First Aid:SKIN-FLUSH WITH LUKEWARM (NOT HOT!) WATER. CALL A PHYSICIAN
    IF FROSTBITE HAS OCCURED. INHALED-IMMEDIATELY REMOVE TO FRESH AIR.
    KEEP PERSON CALM. GIVE ARTIFICIAL RESPIRATION IF NOT BREATHING.
    GIVE OXYG EN IF BREATHING DIFFICULT. CALL A PHYSICIAN.
    EYES-IMMEDIATELY FLUSH WITH WATER FOR 15 MINUTES. CALL A PHYSICIAN.
    INGESTION IS NOT CONSIDERED A POTENTIAL ROUTE OF EXPOSURE.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Autoignition Temp:Autoignition Temp Text:1170F
Extinguishing Media:AS APPROPRIATE FOR COMBUSTIBLES IN AREA.
    EXTINGUISHANT FOR OTHER BURNING MATERIAL IN AREA IS SUFFICIENT TO
    STOP BURNING.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
    FULL FIRE FIGHTER'S PROTECTIVE GEAR. USE WATER TO COOL FIRE EXPOSED
    CONTAINERS.
Unusual Fire/Explosion Hazard:COMPRESSED GAS. CYLINDERS MAY EXPLODE IF
    EXPOSED TO FIRE. DECOMPOSITION MAY OCCUR.

==================  Accidental Release Measures  ==================

Spill Release Procedures:USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT.
    VENTILATE AREA, ESPECIALLY LOW OR ENCLOSED AREAS.  REMOVE OPEN
    FLAMES. USE SCBA FOR LARGE SPILLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN COOL, DRY, WELL VENTILATED
    AREA. DO NOT HEAT ABOVE 125F (52C). USE WITH SUFFICIENT VENTILATION
    TO EXPOSURE BELOW RECOMMENDED LIMITS.
Other Precautions:PRODUCT SHOULD NOT BE USED OR ALLOWED TO BE PRESENT
    WITH HIGH CONENTRATIONS OF AIR ABOOVE ATMOSPHERIC PRESSURE. CONTACT
    W/CHLORINE OR OTHER STRONG OXIDIZING AGENTS SHOULD BE AVOIDED.
    LIQUIFIED GAS UND ER PRESSURE. CLOSE VALVE WHEN NOT IN USE

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE NORMALLY REQUIRED. IF ENGINEERING CONTROLS
    FAIL OR NON-ROUTINE USE OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH
    APPROVED AIR-SUPPLIED RESPIRATOR OR SCBA, AS REQUIRED. USE IAW 29
    CFR 1910.134.
Ventilation:NORMAL VENTILATION IS GENERALLY ADEQUATE. LOCAL EXHAUST
    USED FOR LARGE RELEASES; MECHANICAL FOR LOW OR ENCLOSED AREAS.
Protective Gloves:IMPERVIOUS.
Eye Protection:CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS BEFORE EATING, DRINKING, OR SMOKING.
Supplemental Safety and Health
NSN IS FOR PRODUCT BY ITSELF (PER TIR). NSN FOR CYLINDER ALONE:
    8120-01-348-3119. NSN FOR FILLED CYLINDER IS 6830-00-782-3930.
    ACTUAL ITEM MANAGER IS CODE JDC (LOCAL PURCHASE) PER TIR-NOT CX
    (DSCR)(PL ACED THERE JUST TO FILL IN BOX!).

==================  Physical/Chemical Properties  ==================

HCC:G3
Boiling Pt:B.P. Text:41.4F,5.2C
Decomp Temp:Decomp Text:1170F,632C
Vapor Pres:7809
Vapor Density:3.0
Spec Gravity:1.184
Evaporation Rate & Reference:>1 (CCL4=1)
Solubility in Water:SLIGHT
Appearance and Odor:CLEAR, COLORLESS LIQUIFIED GAS; SLIGHT ETHERAL ODOR
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS, EG. ALUMINUM, ZINC, BERYLIUM, ETC.
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
Hazardous Decomposition Products:TOXIC FUMES OF HYDROCHLORIC & FLUORIC
    ACIDS AND POSSIBLY CARBONYL HALIDES.
Conditions to Avoid Polymerization:POLYMERIZATION WILL NOT OCCUR.

====================  Disposal Considerations  ====================

Waste Disposal Methods:COMPLY WITH LOCAL, STATE AND FEDERAL
    REGULATIONS. RECLAIM BY DISTILLATION OR REMOVE TO A PERMITTED WASTE
    DISPOSAL FACILITY.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.