CHEM SERVICE INC -- 2-BROMOPENTANE, O-616 -- 6810-00N067769
===================== Product Identification ===================== Product ID:2-BROMOPENTANE, O-616 MSDS Date:09/01/1988 FSC:6810 NIIN:00N067769 === Responsible Party === Company Name:CHEM SERVICE INC Box:3108 City:WEST CHESTER State:PA ZIP:19381 Country:US Info Phone Num:215-692-3026 Emergency Phone Num:215-692-3026 CAGE:84898 === Contractor Identification === Company Name:CHEM SERVICE INC Box:3108 City:WEST CHESTER State:PA ZIP:19381 Country:US Phone:215-692-3026 CAGE:84898 Company Name:CHEM SERVICE, INC Address:660 TOWER LN Box:599 City:WEST CHESTER State:PA ZIP:19301-9650 Country:US Phone:610-692-3026 CAGE:8Y898 ============= Composition/Information on Ingredients ============= Ingred Name:PENTANE, 2-BROMO-; (2-BROMOPENTANE) CAS:107-81-3 RTECS #:RZ9800000 OSHA PEL:N/K ACGIH TLV:N/K ===================== Hazards Identification ===================== LD50 LC50 Mixture:LD50: (ORAL,RAT) 150 MG/KG Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:CONTACT LENSES SHOULD NOT BE WORN IN LAB. ALL CHEMICALS SHOULD BE CONSIDERED HAZ - AVOID DIRECT PHYSICAL CONTACT. CAN CAUSE EYE IRRIT. CAN BE HARMFUL IF SWALLOWED. CAN BE IRRIT TO MUCOUS MEMBRANES. CA N BE HARMFUL IF ABSORBED THRU SKIN. CANBE HARMFUL IF INHALED. LACHRYMATOR - CAUSES SEVERE EYE IRRIT. (EFTS OF OVEREXP) Explanation of Carcinogenicity:NOT RELEVANT. Effects of Overexposure:HLTH HAZ:CAN CAUSE SKIN IRRITATION. SUSPECTED CARCINOGEN - MAY PRODUCE CANCER. Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER. ======================= First Aid Measures ======================= First Aid:AN ANTIDOTE IS A SUBSTANCE INTENDED TO COUNTERACT EFT OF POIS. IT SHOULD BE ADMIN ONLY BY MD/TRAINED EMER PERS. MED ADVICE CAN BE OBTAINED FROM POIS CTRL CTR. EYE: FLUSH CONTINUOUSLY W/WATER FOR AT LE AST 15-20 MINS. FLUSH SKIN W/WATER FOR 15-20 MINS. IF NO BURNS HAVE OCCURRED-USE SOAP & WATER TO CLEANSE SKIN. INHAL: REMOVE PATIENT TO FRESH AIR. ADMIN O*2 IF PATIENT IS HAVING DFCLTY BRTHG.(SUPDAT) ===================== Fire Fighting Measures ===================== Flash Point:68.0F,20.0C Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL POWDER OR WATER SPRAY. Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE EQUIPMENT. Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER. ================== Accidental Release Measures ================== Spill Release Procedures:EVAC AREA. WEAR APPROP OSHA/NIOSH/MSHA APPRVD EQUIP. VENT AREA. ABSORB ON VERMICULITE OR SIMILAR MATL. SWEEP UP & PLACE IN AN APPROP CNTNR. HOLD FOR DISP. WASH CONTAMD SURFACES TO REMOVE ANY RESIDUES. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:KEEP TIGHTLY CLSD & STORE IN COOL DRY PLACE. STORE ONLY W/COMPATIBLE CHEMICALS. AVOID CONTACT W/SKIN, EYES & CLTHG. Other Precautions:THIS PRODUCT IS FURNISHED FOR LAB USE ONLY! PRODUCTS MAY NOT BE USED AS DRUGS, COSMETICS, AGRICULTURAL OR PESTICIDAL PRODUCTS, FOOD ADDITIVES OR AS HOUSEHOLD CHEMICALS. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR. Ventilation:THIS CHEMICAL SHOULD BE HANDLED ONLY IN HOOD. Protective Gloves:IMPERVIOUS GLOVES. Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS. Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING ANSI DESIGN CRITERIA. Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health FIRST AID PROC: IF PATIENT HAS STOPPED BRTHG ADMIN ARTF RESP. IF PATIENT IS IN CARD ARREST ADMIN CPR. CONTINUE LIFE SUPPORTING MEASURES UNTIL MED ASSIST HAS ARRIVED. ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:243F,117C Spec Gravity:1.223 Solubility in Water:IMMISCIBLE Appearance and Odor:COLORLESS LIQUID W/ETHER LIKE ODOR. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG BASES, STRONG OXIDIZING AGENTS. DO NOT USE MAGNESIUM/ALUMINUM OR THEIR ALLOYS AS CONTAINERS. Stability Condition to Avoid:LOW REACTIVITY. FLAMMABLE. Hazardous Decomposition Products:DECOMPOSITION LIBERATES TOXIC FUMES. DECOMPOSITION PRODUCTS ARE CORROSIVE. ==================== Disposal Considerations ==================== Waste Disposal Methods:BURN IN CHEMICAL INCINERATOR EQUIPPED W/AN AFTER BURNER & SCRUBBER. DISPOSE OF IN ACCORDANCE W/LOCAL, STATE & FEDERAL REGULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.