MEDECO SECURITY LOCK -- KEY LUBE -- 9150-00N079649
===================== Product Identification =====================
Product ID:KEY LUBE
MSDS Date:09/23/1996
FSC:9150
NIIN:00N079649
=== Responsible Party ===
Company Name:MEDECO SECURITY LOCK
Box:3075
City:SALEM
State:VA
ZIP:24163
Country:US
Info Phone Num:703-360-5000
Emergency Phone Num:800-424-9300(CHEMTREC)
CAGE:56337
=== Contractor Identification ===
Company Name:MEDECO SECURITY LOCK
Box:3075
City:SALEM
State:VA
ZIP:24163
Country:US
Phone:703-360-5000
CAGE:56337
============= Composition/Information on Ingredients =============
Ingred Name:LIGHT ALIPHATIC SOLVENT NAPHTHA; (SOLVENT NAPHTHA, LIGHT
SLIPHATIC). VP: 40 @ 20C
CAS:84742-89-8
Fraction by Wt: <30%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:FLUOROCARBON TELOMER
Fraction by Wt: <10%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:PROPELLANT. (CONSISTING OF INGS 4 & 5). VP: >760 @ 20C.
Fraction by Wt: <70%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:PROPANE. VP: >760 @20C
CAS:74-98-6
RTECS #:TX2275000
Fraction by Wt: (20%)
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT; 9495
Ingred Name:PROPANE, 2-METHYL-; (ISOBUTANE). VP: >760 @ 20
CAS:75-28-5
RTECS #:TZ4300000
Fraction by Wt: (50%)
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL:MAY CAUSE IRRITATION OF
RESPIRATORY TRACT, NAUSEA, DIZZINESS, HEADACHE AND DEPRESSION OF
THE CNS AND IRREGULAR HEARTBEAT. INTENTIONAL MISUSE OF THIS PRODUCT
BY DELIBERATELY CONCENTRATING AND INHALING CAN BE HARMFUL OR
FATAL. INGEST:MAY CAUSE GI IRRITATION AND DEPRESSION OF CNS.
SKIN:MAY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:CAUSE IRRITATION. EYE CONTACT:MAY
CAUSE IRRITATION. CHRONIC: PROLONGED OR REPEATED CONTACT MAY CAUSE
DERMATITIS. MAY CAUSE SKIN IRRITATION ON PROLONGED OR REPEATED
CONTACT.
Medical Cond Aggravated by Exposure:NONE RECOGNIZED.
======================= First Aid Measures =======================
First Aid:INHAL:IF USER EXPERIENCES BREATHING DIFFICULTY, MOVE TO AIR
FREE OF VAPORS. ADMINISTER OXYGEN OR ARTF RESP UNTIL MED ASSISTANCE
CAN BE RENDERED. INGEST:DO NOT INDUCE VOMIT. CALL POSION CONTROL
CENTER, HOSPITAL, EMERGENCY ROOM OR PHYSICIAN IMMED. SKIN CONTACT:
WASH WITH SOAP AND WATER. EYE CONTACT: FLUSH W/LARGE QUANTITIES OF
WATER FOR AT LEAST 15 MIN. IF IRRIT FROM CONTACT PERSISTS, GET MED
ATTN.
===================== Fire Fighting Measures =====================
Extinguishing Media:USE CARBON DIOXIDE, DRY POWDER OR FOAM.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . STORAGE CONTAINERS EXPOSED TO FIRE SHOULD BE KEPT COOL
W/WATER SPRAY TO PREVENT PRESSURE BUILD-UP.
Unusual Fire/Explosion Hazard:CONTENTS UNDER PRESS. DO NOT PUNCTURE.
INCIN/STORE ABOVE 120F. EXPOS TO HEAT/PRLNG EXPOS TO SUN MAY CAUSE
BURSTING. ISOLATE FROM HEAT, ELEC EQUIP, (SUPDAT)
================== Accidental Release Measures ==================
Spill Release Procedures:AVOID BREATHING VAPOR. VENTILATE AREA. FLUSH
LARGE SPILLS OF MATERIAL INTO SUITABLE RETAINING AREA OR CONTAINER
WITH LARGE QUANTITIES OF WATER. SMALL SPILL CAN BE ABSORBED BY
APPROPRIATE INERT ABSORBE NT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE NEAR FLAME OR AT ELEVATED
TEMPERATURES
Other Precautions:READ CAREFULLY ALL CAUTIONS AND DIRECTIONS ON PRODUCT
LABEL BEFORE USE. SINCE EMPTY CONTAINER RETAINS RESIDUE, FOLLOW ALL
LABEL WARNING EVEN AFTER CONTAINER IS EMPTY. DISPOSE OF ANY
CONTAINER ACCORDIN G TO LOCAL REGULATIONS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:FOR OSHA CONTROLLED WORK PLACE, USE ONLY W/ADEQ
VENT UNDER ENGINEERED AIR CONTROL SYS DESIGNED TO PROVIDE MAX
APPROP TLV. FOR OCCAS USE WHERE ENGINEERED AIR CONTROL IS NOT
FEASIBLE, USE NIOSH APPRVD R ESP. FOR OCCAS CONSUMER USE, (SUPDAT)
Ventilation:ADEQUATE VENTILATION MUST BE PROVIDED. SEE RESPIRATORY
PROTECTION.
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS THOROUGHLY AFTER USE. BEFORE REUSE,
THOROUGHLY CONTAM ANY CLTHG/PROT EQUIP WHICH HAS BEEN (SUPDAT)
Supplemental Safety and Health
EXPLO HAZ: SPARKS, OPEN FLAMES AND HOT SURFACES. RESP PROT: USE ONLY
WITH ADEQUATE VENTILATION. EYE PROT: AND FULL LENGTH FACESHIELD .
HYGIENE PRACT: CONTAMINATED BY PRIOR USE.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:>185F,>85C
Vapor Pres:SEE ING
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:95.0
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY PRODUCE
HYDROGEN CHLORIDE, HYDROGEN FLUORIDES, AND SAMLL AMOUNTS OF
PHOSGENE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH APPLICABLE LOCAL,
STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.