CHEM SERVICE INC -- TETRACHLOROMETHANE, 0-620 -- 6810-00N043687
===================== Product Identification =====================
Product ID:TETRACHLOROMETHANE, 0-620
MSDS Date:03/16/1992
FSC:6810
NIIN:00N043687
=== Responsible Party ===
Company Name:CHEM SERVICE INC
Box:3108
City:WEST CHESTER
State:PA
ZIP:19381
Country:US
Info Phone Num:215-692-3026
Emergency Phone Num:215-692-3026
CAGE:84898
=== Contractor Identification ===
Company Name:CHEM SERVICE INC
Box:3108
City:WEST CHESTER
State:PA
ZIP:19381
Country:US
Phone:215-692-3026
CAGE:84898
Company Name:CHEM SERVICE, INC
Address:660 TOWER LN
Box:599
City:WEST CHESTER
State:PA
ZIP:19301-9650
Country:US
Phone:610-692-3026
CAGE:8Y898
============= Composition/Information on Ingredients =============
Ingred Name:EXPLAN OF CARCIN:ANTICIPATED TO BE CARCINOGEN.
RTECS #:9999999ZZ
Ingred Name:CARBON TETRACHLORIDE; (TETRACHLOROMETHANE) (SARA III).
LD50:(ORAL,RAT) 2800 MG/KG.
CAS:56-23-5
RTECS #:FG4900000
OSHA PEL:2 PPM
ACGIH TLV:5 PPM, S
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS
Ozone Depleting Chemical:1
Ingred Name:SUPDAT:CHLOROCARBONS .
RTECS #:9999999ZZ
Ingred Name:FIRST AID PROC:IS HAVING DFCLTY BRTHG. IF PATIENT HAS
STOPPED BRTHG ADMIN ARTF RESP. IF PATIENT IS IN CARDIAC (ING 4)
RTECS #:9999999ZZ
Ingred Name:ING 3:ARREST ADMIN CPR. CONTINUE LIFE SUPPORTING MEASURES
UNTIL MEDICAL ASSISTANCE HAS ARRIVED.
RTECS #:9999999ZZ
Ingred Name:OTHER PREC:FOR LAB USE ONLY! OUR PRODS MAY NOT BE USED AS
DRUGS, COSMETICS, AGRICULTURAL/PESTICIDAL PRODS, FOOD (ING 6)
RTECS #:9999999ZZ
Ingred Name:ING 5:ADDITIVES/AS HOUSEHOLD CHEMS. NO SMOKING IN AREA OF
USE. DO NOT USE IN GEN VICIN OF ARC WELDING, OPEN (ING 7)
RTECS #:9999999ZZ
Ingred Name:ING 6:FLAMES/HOT SURFS. HEAT &/OR UV RADIA MAY CAUSE FORM
OF HCL &/OR PHOSGENE .
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:SEE INGREDIENT.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SUSPECTED CARCIN - MAY PRDCE CANCER.
MAY BE HARMFUL/FATAL IF ABSORBED THRU SKIN, INHALED/SWALLOWED.
PRLNG EXPOS MAY CAUSE NAUS, HDCH, DIZZ &/OR EYE DMG. INGEST MAY
CAUSE DIARR. EXPOS CAN CAUSE LIVER/K IDNEY DMG. RPTD EXPOS TO VAPS
&/OR DUSTCAN CAUSE EYE INJURY. CAN CAUSE SENSIT BY SKIN CONT. CAN
CAUSE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:CARBON TETRACHLORIDE:IARC MONOGRAPHS,
SUPP, VOL 7, PG 143, 1987:GRP 2B. NTP 6TH ANNUAL REPORT ON CARCINS,
1991: (ING 8)
Effects of Overexposure:HLTH HAZ:DELAYED ADVERSE HLTH EFTS. CAN CAUSE
GI DISTURBS. BASED ON TOX OF CMPDS OF SIMILAR STRUCTURE THIS MATL
IS PROBABLY HIGHLY HAZ. CAN CAUSE EYE/SKIN IRRIT. DUST &/OR VAPS
CAN CAUSE IRRIT TO RESP TRACT. CAN BE IRRIT TO MUC MEMBS. MAY BE
RAPIDLY ABSORBED THRU SKIN W/POTNTL ADVERSE HEALTH EFTS. CAN CAUSE
(SUPP DAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:ANTIDOTE IS SUBSTANCE INTENDED TO COUNTERACT EFT OF POIS. IT
SHOULD BE ADMIN ONLY BY MD/TRAINED EMER PERS. MED ADVICE CAN BE
OBTAINED FROM POIS CTL CTR. INGEST:CALL MD IMMED . EYES:FLUSH
CONTINU OUSLY W/WATER FOR AT LST 15-20 MINS. SKIN:FLUSH W/WATER FOR
15-20 MINS. IF NO BURNS HAVE OCCURRED-USE SOAP & WATER TO CLEANSE
SKIN. INHAL: REMOVE PATIENT TO FRESH AIR. ADMIN OXYGEN IF PATIENT
(ING 3)
===================== Fire Fighting Measures =====================
Flash Point:NON-FLAMMABLE
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL POWDER OR SPRAY.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA &
FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NO EXPLOSION LIMITS ARE AVAILABLE FOR
THIS COMPOUND. THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE HCL &
PHOSGENE .
================== Accidental Release Measures ==================
Spill Release Procedures:EVACUATE AREA. WEAR APPROPRIATE OSHA REGULATED
EQUIPMENT. VENTILATE AREA. ABSORB ON VERMICULITE OR SIMILAR
MATERIAL. SWEEP UP & PLACE IN APPROPRIATE CONTAINER. HOLD FOR
DISPOSAL. WASH CONTAMINATED SUR FACES TO REMOVE ANY RESIDUES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP TIGHTLY CLSD IN COOL, DRY PLACE.
STORE ONLY W/COMPAT CHEMS. ALL CHEMS SHOULD BE CONSIDERED HAZ -
AVOID DIRECT PHYSICAL CONTACT!
Other Precautions:AVOID CONT W/EYE, SKIN & CLTHG. AVOID CONSUMPTION OF
ALCOHOL BEFORE & AFTER HNDLG OF THIS CMPD BECAUSE IT WILL INCR TOX
OF CMPD. PERS NOT SPECIFICALLY & PROPERLY TRAINED SHOULD NOT HANDLE
THIS CHEM/IT S CNTNR. THIS PROD IS FURNISHED (ING 5)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . EYE PROT: & FULL LENGTH FACESHIELD .
Ventilation:THIS CHEMICAL SHOULD BE HANDLED ONLY IN A HOOD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APRV CHEM SFTY GOGG (RESPIR PROT)
Other Protective Equipment:ANSI APRV EMERGENCY EYE WASH & DELUGE SHOWER
. WEAR APPROPRIATE NIOSH/MSHA APPROVED SAFETY EQUIPMENT.
Work Hygienic Practices:CONTACT LENSES SHOULD NOT BE WORN IN THE
LABORATORY.
Supplemental Safety and Health
EFTS OF OVEREXP:NERV SYS INJURY. CAN CAUSE DELAYED LUNG INJURY.
CHLOROCARBON MATLS HAVE PRDCD SENSIT OF MYOCARDIUM TO EPINEPHRINE
IN LAB ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS
(E.G ., EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR LIFE-
SUSTAINING USES IN HUMANS ACUTELY/CHRONICALLY EXPOS TO (ING 2)
================== Physical/Chemical Properties ==================
HCC:T3
Boiling Pt:B.P. Text:170F,77C
Melt/Freeze Pt:M.P/F.P Text:-9F,-23C
Vapor Pres:91 @ 20C
Spec Gravity:1.594
Solubility in Water:INSOL (IMMISCIBLE)
Appearance and Odor:COLORLESS LIQUID; ETHER LIKE ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE W/STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:AIR SENSITIVE. DECOMPOSES UNDER ALKALINE
CONDITIONS.
Hazardous Decomposition Products:DECOMP PRODS ARE CORR. DECOMP
LIBERATES TOXIC FUMES. HCL, PHOSGENE .
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AFTERBURNER
& SCRUBBER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.